Test Code SLFA Cryptococcus Antigen Screen with Titer, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 14 days |
| Frozen | 14 days |
Testing Algorithm
If result is positive, Cryptococcus titer will be performed at an additional charge.
Reflex Tests
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| SLFAT | Cryptococcus Ag Titer, LFA, S | Yes | No |
Useful For
Aiding in the diagnosis of cryptococcosis
This test should not be used as a test of cure or to guide treatment decisions.
This test should not be used as a screening procedure for the general populations.
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 2 daysReporting Name
Cryptococcus Ag Screen w/Titer, SReference Values
Negative
Method Name
Lateral Flow Assay (LFA)
Performing Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
87899