Sign in →

Test Code LID Lidocaine, Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.


Children's Mercy Hospital Note:

CMH Collection: 1 mL blood in Red vacutainer

Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days

Useful For

Assessing optimal lidocaine dosing during the acute management of ventricular arrhythmias following myocardial infarction or during cardiac manipulation such as surgery

 

Assessing potential lidocaine toxicity

Reject Due To

Gross hemolysis Reject

Day(s) Performed

Monday through Saturday

Report Available

Same day/1 to 2 days

Reporting Name

Lidocaine, S

Reference Values

Therapeutic: 1.5-5.0 mcg/mL

Critical value: >6.0 mcg/mL

Method Name

Enzyme-Multiplied Immunoassay Technique (EMIT)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

80176