Test Code LID Lidocaine, Serum
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.
CMH Collection: 1 mL blood in Red vacutainer
Specimen Minimum Volume
0.25 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum Red | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen | 14 days |
Useful For
Assessing optimal lidocaine dosing during the acute management of ventricular arrhythmias following myocardial infarction or during cardiac manipulation such as surgery
Assessing potential lidocaine toxicity
Reject Due To
Gross hemolysis | Reject |
Day(s) Performed
Monday through Saturday
Report Available
Same day/1 to 2 daysReporting Name
Lidocaine, SReference Values
Therapeutic: 1.5-5.0 mcg/mL
Critical value: >6.0 mcg/mL
Method Name
Enzyme-Multiplied Immunoassay Technique (EMIT)
Performing Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
80176