Sign in →

Test Code HYPOG Hypoglycemic Agent Screen, Serum

Important Note

CMH Cerner Order: Ref Misc


Specimen Required


Patient Preparation: Specimen must be collected during an episode of hypoglycemia.

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume:1.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Children's Mercy Hospital Note:

CMH COLLECTION: 1mL blood in a Red vacutainer

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Frozen (preferred) 28 days
  Refrigerated  28 days
  Ambient  7 days

Useful For

Evaluation of suspected insulinoma characterized by hypoglycemia and increased serum insulin concentration

 

Detecting drugs that stimulate insulin secretion

 

Drugs detected by this procedure are:

-The first-generation sulfonylureas: chlorpropamide (Diabinese), tolazamide, and tolbutamide (Orinase)

-The second-generation sulfonylureas: glimepiride (Amaryl), glipizide (Glucotrol), and glyburide (Glibenclamide)

-The meglitinides: repaglinide (Prandin) and nateglinide (Starlix)

-The thiazolidinediones: pioglitazone (Actos) and rosiglitazone (Avandia)

 

This test is not intended for therapeutic drug monitoring but could be used to monitor compliance.

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Day(s) Performed

Monday, Wednesday, Friday

Report Available

2 to 6 days

Reporting Name

Hypoglycemic Agent Screen, S

Reference Values

Negative

Screening cutoff concentrations

Chlorpropamide: 100 ng/mL

Glimepiride: 20 ng/mL

Glipizide: 5 ng/mL

Glyburide: 5 ng/mL

Nateglinide: 5 ng/mL

Pioglitazone: 20 ng/mL

Repaglinide: 5 ng/mL

Rosiglitazone: 20 ng/mL

Tolazamide: 50 ng/mL

Tolbutamide: 20 ng/mL

 

Note: If a drug is detected at a concentration greater than the cutoff, the report will indicate that specific drug is positive. The test cutoff listed for each drug is lower than the concentration that will cause increased insulin and decreased glucose.

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

80377

G0480-(if appropriate)