Lactate Dehydrogenase (LDH)

Collection Requirements

Source: blood
Container(s):

  • Preferred: Lithium heparin mint green gel
  • Acceptable: Red or Red gel

Volume: 1 mL in vacutainer or 400 uL in microtainer

Turn Around Time

STAT: 1 hour
Routine: 2-4 hours

Availability

STAT
Routine

Lab Processing Instructions

Specimen: plasma or serum
Spin, separate, and store at room temperature
Do NOT refrigerate or freeze
Must be tested within 48 hours of collection

Performing Laboratory

Adele Hall
Kansas

Adele Hall Lab Section

Chemistry

Instrumentation/Methodology

Vitros

Reference Ranges

Age Reference Range (U/L)
0-5 days 416-957
6 days - 3 years 223-409
4-6 years 209-401
7-9 years 187-334
10-13 years 169-343
14-15 years Male 160-325 , Female 174-258
16-18 years 151-298

≥ 19 years

139-275

 

CPT

83615