Test Code F_10 Coagulation Factor X Activity Assay, Plasma


Ordering Guidance


Coagulation testing is highly complex, often requiring the performance of multiple assays and correlation with clinical information. For that reason, consider ordering a Coagulation Consultation.



Necessary Information


 



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Light-blue top (3.2% sodium citrate)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Platelet-poor plasma

Collection Instructions:

1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.

2. Within 4 hours of collection, centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.

3. Aliquot plasma into a separate plastic vial, leaving 0.25 mL in the bottom of the centrifuged vial.

4. Immediately freeze plasma (no longer than 4 hours after collection) at -20° C or, ideally, -40° C or below.

Additional Information:

1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.

2. Each coagulation assay requested should have its own vial.


Children's Mercy Hospital Note:

CMH COLLECTION: 2.7 mL in light blue vacutainer

Specimen Minimum Volume

Platelet-poor plasma: 0.5 mL

Specimen Stability Information

Specimen Type Temperature Time
Plasma Na Cit Frozen 14 days

Useful For

Diagnosing deficiency of coagulation factor X, congenital or acquired

 

Evaluating hemostatic function in liver disease

 

Investigation of prolonged prothrombin time or activated partial thromboplastin time

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Day(s) Performed

Monday through Friday

Report Available

1 to 3 days

Reporting Name

Coag Factor X Assay, P

Reference Values

Adults: 70-150%

Normal, full-term newborn infants or healthy premature infants may have decreased levels (≥15-20%), which may not reach adult levels for 180 or more days postnatal.*

*See Pediatric Hemostasis References section in Coagulation Guidelines for Specimen Handling and Processing

Method Name

Optical Clot-Based

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

85260