Sign in →

Test Code FLEC Flecainide, Serum


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions:

1. Draw blood immediately before next scheduled dose.

2. Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.


Children's Mercy Hospital Note:

CMH COLLECTION: 3 mL in red vacutainer

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Useful For

Optimizing flecainide dosage

 

Assessing flecainide toxicity

 

Monitoring compliance

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Day(s) Performed

Monday through Friday

Report Available

2 to 5 days

Reporting Name

Flecainide, S

Reference Values

Trough Value

0.2-1.0 mcg/mL: Therapeutic concentration

>1.0 mcg/mL: Toxic concentration

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

80181