Platelet Function Screen
Collection Requirements
Source: blood
Containers: Draw both
- Two 2.7 mL Sodium citrate light blue
- EDTA lavender
Volume:
- Light blue: 2.7 mL in each vacutainer filled to the line
- Lavender: 1 mL in vacutainer or 250 uL in microtainer
Special Instructions
Send to the Lab immediately
Must be tested within 4 hours of collection
Turn Around Time
4 hours
Availability
Routine
Algorithm
Platelet count <100 and/or Hematocrit <30 or >50: test not performed
Platelet count >100 and/or Hematocrit >30 and <50: COL/EPI testing proceeds
- COL/EPI <160 sec: only COL/EPI reported
- COL/EPI >160 sec: COL/EPI and COL/ADP reported
Lab Processing Instructions
Specimen: whole blood
Room temperature
Offsites:
- Send whole blood at room temperature with a STAT courier
Performing Laboratory
Adele Hall
Adele Hall Lab Section
Hematology
Instrumentation/Methodology
Dade PFA-100
Reference Ranges
COL/EPI = 83-160 sec
COL/ADP = 55-120 sec
CPT
85576
85576 additional (if appropriate)