Antithrombin III (AT3)
Collection Requirements
Source: blood
Container: Sodium citrate light blue
Volume: 2.7 mL in vacutainer filled to the
line
Special Instructions
If patient hematocrit is >55, call Hematology for special collection tube
Turn Around Time
STAT: 1 hour
Routine: 4 hours
Availability
STAT
Routine
Lab Processing Instructions
Specimen: plasma
Double spin and separate
Freeze if testing will not be completed within 1 hour of
processing
Offsites:
- STAT: Send plasma at room temperature with a STAT courier
- Routine: Send plasma on dry ice
Performing Laboratory
Adele Hall
Adele Hall Lab Section
Hematology
Instrumentation/Methodology
Stago STAR
Reference Ranges
Age (days) | Reference Range (%) |
---|---|
0-4 | 39-87 |
5-29 | 41-93 |
30-89 | 48-108 |
90-179 | 73-121 |
> 180 | 79-131 |
CPT
85300