Antithrombin III (AT3)

Collection Requirements

Source: blood
Container: Sodium citrate light blue
Volume: 2.7 mL in vacutainer filled to the line

Special Instructions

If patient hematocrit is >55, call Hematology for special collection tube

Turn Around Time

STAT: 1 hour
Routine: 4 hours

Availability

STAT
Routine

Lab Processing Instructions

Specimen: plasma 
Double spin and separate
Freeze if testing will not be completed within 1 hour of processing

 

Offsites:

  • STAT: Send plasma at room temperature with a STAT courier
  • Routine: Send plasma on dry ice

Performing Laboratory

Adele Hall

Adele Hall Lab Section

Hematology

Instrumentation/Methodology

Stago STAR

Reference Ranges

Age (days) Reference Range (%)
0-4 39-87
5-29 41-93
30-89 48-108
90-179 73-121
> 180 79-131

 

CPT

85300