Sign in →

Test Code ARBI Acetylcholine Receptor (Muscle AChR) Binding Antibody, Serum


Ordering Guidance


Standalone testing (this test) is recommended in certain situations.

 

This test should not be requested in patients who have recently received radioisotopes, therapeutically or diagnostically, because of potential assay interference. The specific waiting period before specimen collection will depend on the isotope administered, the dose given, and the clearance rate in the individual patient. Specimens will be screened for radioactivity prior to analysis. Radioactive specimens received in the laboratory will be held for 1 week and assayed if sufficiently decayed or canceled if radioactivity remains.



Specimen Required


Patient Preparation: For optimal antibody detection, specimen collection is recommended prior to initiation of immunosuppressant medication.

Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL


Children's Mercy Hospital Note:

CMH COLLECTION: 4.0 mL in red gel vacutainer

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  72 hours

Testing Algorithm

This is the primary diagnostic test for myasthenia gravis.

Useful For

Supporting the diagnosis of autoimmune myasthenia gravis (MG) in adults and children

 

Distinguishing autoimmune from congenital MG in adults and children or other acquired forms of neuromuscular junction transmission disorders

 

An adjunct to the test for P/Q-type calcium channel binding antibodies as a diagnostic aid for Lambert-Eaton myasthenic syndrome

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Day(s) Performed

Monday through Sunday

Report Available

3 to 6 days

Reporting Name

ACh Receptor (Muscle) Binding Ab

Reference Values

≤0.02 nmol/L

Method Name

Radioimmunoassay (RIA)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

86041